alarm systems, cctv systems, access control, doorphone systems, PA systems, fire systems, ip camera. Inverters. Solar panels. solar controllers. Batteries. Surge Protectors. Emergency power sources. Charging device.

  • En
  • Lv
  • Ru
  • Pl
  • Login with:
  • anazana
  • facebook
Search form
Search
  • Home
  • Solar energy
  • Accessories, cables, mounts, connectors
  • CCTV
  • Alarm systems
  • Access control
  • Intercom systems
  • Fire safety systems
  • Videodoorphones, doorphones and intercoms
  • Electric gate automation systems and barriers
  • Networking
  • Sound systems
  • Switching and Server Cabinets, accessories
  • Tools and accessories
  • Cables covers and accessories
  • Power supply and accumulators
  • HDMI
  • Accessories for caravans and campers
  • Wiring
  • Solar energy
    • Solar panels
    • Solar controllers
    • Accumulators
    • DC/DC Power Inverters
    • DC/DC Power Inverters
    • Voltage stabilizers
    • Battery chargers
    • Accessories, cables, mounts, connectors
    • Solar inverters
    • Solar sets
    • Mounting elements
    • Inverter power generator
    • Wind energy
  • Wind energy
  • Contacts

DC / DC protection of PV installations PVP-10 700V / 16A

#
DC / DC protection of PV installations PVP-10 700V / 16A
Product info form
Price 97.00 73.00 EUR
SKU AZO00D1240
Add to cart, ask a question
Out of stock
product not available
Please select options
DC fuse holder for LEADER ZTPV-25B photovoltaic applications
• rated short-circuit capacity Icn with the 33kA fuse link installed
• rated current up to 32A
• size of the fuse link 10x38 mm
• Use category DC-20B
• made in accordance with IEC / EN 60947-3
• 1000 VDC rated voltage
• rated current DC-20B 1000 VDC 32A
• number of poles 2
• Use category DC-20B
• short-circuit breaking capacity of 33kA
• maximum power loss of 4W inserts
• dimensions 36x83mm
• standard TS-35mm rail mounting
• degree of protection IP20
• working temperature -30 + 70 ° C
• size of the fuse link 10 X 38 mm
• weight 0.14 kg

LKTD2 –PV1000 overvoltage limiter
• manufactured in accordance with EN 50539-11
• rated discharge current In 20 kA (8 / 20us) per module
• maximum discharge current imax 40 kA (8 / 20us)
• maximum continuous operating voltage UCPV 1000V DC
• for grounded and ungrounded PV systems
• removable insole
• type of the PV-T2 surge arrester (class II, C, type 2)
• MOV insert (varistor)
• thermal protection function
• protection mode minus to PE, plus to PE, minus to plus
• rated operational voltage Un 1000 VDC
• maximum continuous operating voltage 1300 VDC
• 1100 VDC maximum open circuit voltage
• rated discharge current In (8 / 20us) 20 kA
• maximum discharge current Imax (8 / 20us) 40 kA
• Itotal total discharge current (8 / 20us) 40 kA
• voltage protection level Up at In <4kV
• leakage current Ipf at Uref DC <50 uA
• leakage current Ipe at Uref AC <1 mA
• maximum short-circuit current 1000 A
• number of ports 2
• LV DC system type, grounded PV; DC, unearthed PV system;
• limiter mode during OCM overload
• width 36 mm
• height 83 mm
• standard TS-35mm rail mounting
• degree of protection IP40, terminals IP20
• elevator clamp, M5 screw
• cross-section of connection terminals 2.5 - 25 mm2
• tightening torque of the clamping screws 2-3.5 Nm
• internal use
• installation class III
• ambient temperature -5 +40 ° C
• absolute altitude <= 2000m
• climatic resistance 5 - 95%
• weight 0.24 kg
  • DC / DC protection of PV installations PVP-10 700V / 16A
  • DC / DC protection of PV installations PVP-10 700V / 16A
  • DC / DC protection of PV installations PVP-10 700V / 16A